Maxsys and MX Series Software Administrator’s Guide 183
Advanced Tab
Testing Card Stock Elements
Once the Pattern Match/OCV elements are placed on the card, the Verification
Module then compares the elements on the front and/or back of the card to either
a pre-defined file, data element, or contents of a live data stream. An acceptance
threshold must be established as the criteria for either accepting or rejecting the
card. Perform the following procedure to test the card stock elements.
1. Place and config
ure Pattern Match/OCR elements as described above.
2. To te
st each element individually, click on that element and then click Test in
the properties pane. To test all of the elements on the card click Test All. The
result(s) will open in a new window as shown below.
In the example above, the pattern match passed with an average score of 99
and a minimum score of 99. The minimum score is entered into the Pass
Threshold box in the dialog.
In the examples below, three tests of OCV characters yield different results.
• I
n the first example, the test failed with an average score of 15, with the
program only recognizing the first two characters.
Parameter Description
Width/Height Scaling The degree to which the OCV font characters
have been scaled from their original size
Rotation Degrees The degree to which the OCV font characters will
be read from the X/Y reference point